We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: The absence of population-stratified cardiovascular magnetic resonance (CMR) reference ranges from large cohorts is a major shortcoming for clinical care. OBJECTIVES: This paper provides age-, sex-, and ethnicity-specific CMR reference ranges for atrial and ventricular metrics from the Healthy Hearts Consortium, an international collaborative comprising 9,088 CMR studies from verified healthy individuals, covering the complete adult age spectrum across both sexes, and with the highest ethnic diversity reported to date. METHODS: CMR studies were analyzed using certified software with batch processing capability (cvi42, version 5.14 prototype, Circle Cardiovascular Imaging) by 2 expert readers. Three segmentation methods (smooth, papillary, anatomic) were used to contour the endocardial and epicardial borders of the ventricles and atria from long- and short-axis cine series. Clinically established ventricular and atrial metrics were extracted and stratified by age, sex, and ethnicity. Variations by segmentation method, scanner vendor, and magnet strength were examined. Reference ranges are reported as 95% prediction intervals. RESULTS: The sample included 4,452 (49.0%) men and 4,636 (51.0%) women with average age of 61.1 ± 12.9 years (range: 18-83 years). Among these, 7,424 (81.7%) were from White, 510 (5.6%) South Asian, 478 (5.3%) mixed/other, 341 (3.7%) Black, and 335 (3.7%) Chinese ethnicities. Images were acquired using 1.5-T (n = 8,779; 96.6%) and 3.0-T (n = 309; 3.4%) scanners from Siemens (n = 8,299; 91.3%), Philips (n = 498; 5.5%), and GE (n = 291, 3.2%). CONCLUSIONS: This work represents a resource with healthy CMR-derived volumetric reference ranges ready for clinical implementation.

Original publication

DOI

10.1016/j.jcmg.2024.01.009

Type

Journal article

Journal

JACC Cardiovasc Imaging

Publication Date

26/03/2024

Keywords

artificial intelligence, automated analysis, cardiovascular magnetic resonance, ethnicity, healthy reference ranges, sex differences