We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: There are limited data on the use of a remote robotic catheter system (RCS) for mitral isthmus (MI) ablation. METHODS: This single-center, prospective, matched control study included 45 patients who underwent atrial fibrillation ablation using a remote RCS compared to 45 patients who underwent conventional ablation. All patients had circumferential pulmonary vein isolation (PVI), roof, and MI ablation. RESULTS: There were no significant differences in baseline clinical characteristics. There were no significant differences in MI block (RCS: 44/45 [98%] vs CONTROL: 43/45 [96%], P = 1.0), roof block (RCS: 45/45 [100%] vs CONTROL: 44/45 [98%], P = 1.0), and PVI (RCS: 45/45 [100%] vs CONTROL: 45/45 [100%], P = 1.0). Ablation and procedural times were similar in both arms. Using RCS, mean total MI ablation and procedure times were 13 ± 6 minutes and 23 ± 15 minutes, respectively. Coronary sinus (CS) ablation was significantly less in the RCS arm (48% vs 72%, P = 0.03). It was possible to "drive" the ablation catheter into the distal CS using the RCS in 19/22 (86%) patients. There was a significant trend of reduction in mean MI ablation (P = 0.008) and procedural times (P = 0.004) over the course of the study period. There was a significant reduction in fluoroscopy time in the RNS arm (33 ± 17 minutes vs 49 ± 20 minutes, P = 0.0004). CONCLUSION: It is feasible and safe to use a remote RCS for MI ablation, including "driving into the CS." MI block was achieved in 98% with a significant reduction in the need for CS ablation (48%). There is a short learning curve.

Original publication

DOI

10.1111/pace.12201

Type

Journal article

Journal

Pacing Clin Electrophysiol

Publication Date

11/2013

Volume

36

Pages

1364 - 1372

Keywords

atrial fibrillation, mitral isthmus, radiofrequency ablation, robotic catheter system, Atrial Fibrillation, Catheter Ablation, Equipment Design, Equipment Failure Analysis, Female, Humans, Male, Middle Aged, Mitral Valve, Postoperative Complications, Robotics, Surgery, Computer-Assisted, Telemedicine, Treatment Outcome