We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: The purpose of this study was to evaluate long-term vascular responses as long as 2 years after implantation of polymer-based, paclitaxel-eluting stents in contrast to uncoated stents. METHODS AND RESULTS: TAXUS II is a randomized, double-blind trial comparing slow-release (SR) and moderate-release (MR) TAXUS stents with bare-metal control stents (BMSs). One hundred sixty-one event-free patients (SR, 43; MR, 41; and BMS, 77) underwent serial intravascular ultrasound (IVUS) analysis after the procedure and at 6 months and 2 years. At 2 years, neointimal responses continued to be significantly suppressed in the SR and MR groups when compared with the BMS group (BMS, 1.49+/-1.12 mm2; SR, 0.94+/-0.76 mm2 [P=0.004]; and MR, 1.06+/-0.90 mm2 [P=0.02]). Between 6 months and 2 years, the BMS group showed compaction of the neointima (Delta, -0.22+/-1.05 mm2 [P=0.08]). In contrast, both the SR and MR groups exhibited an increase (Delta SR, 0.30+/-0.76 mm2 (P=0.01); MR, 0.41+/-0.94 mm2 [P=0.009]). Between 6 months and 2 years, the initial increase in plaque outside the stent regressed in the BMS and SR groups to levels comparable to those after the procedure, whereas expansive remodeling partially regressed in the MR group (Delta between after the procedure and 2 years BMS, -0.34+/-1.28 mm2 [P=0.05]; SR, -0.02+/-1.40 mm2 [P=0.93]; MR, 0.32+/-1.56 mm2 [P=0.27]). CONCLUSIONS: The 2-year follow-up demonstrates that neointimal suppression was dose independent and that this effect was still sustained at 2 years. However, the increase in area outside the stent seen at 6 months regressed to different extents in a dose-dependent manner at 2 years.

Original publication

DOI

10.1161/CIRCULATIONAHA.105.558601

Type

Journal article

Journal

Circulation

Publication Date

20/12/2005

Volume

112

Pages

3876 - 3883

Keywords

Aged, Antineoplastic Agents, Phytogenic, Cell Proliferation, Dose-Response Relationship, Drug, Double-Blind Method, Female, Follow-Up Studies, Graft Occlusion, Vascular, Humans, Male, Middle Aged, Paclitaxel, Polymers, Stents, Tunica Intima, Ultrasonography, Interventional