Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: We investigate the influence of moving blood-attenuation effects when using "delay alternating with nutation for tailored excitation" (DANTE) pulses in conjunction with blood oxygen level dependent (BOLD) of functional MRI (fMRI) at 3 T. Based on the effects of including DANTE pulses, we propose quantification of cerebral blood volume (CBV) changes following functional stimulation. METHODS: Eighteen volunteers in total underwent fMRI scans at 3 T. Seven volunteers were scanned to investigate the effects of DANTE pulses on the fMRI signal. CBV changes in response to visual stimulation were quantified in 11 volunteers using a DANTE-prepared dual-echo EPI sequence. RESULTS: The inflow effects from flowing blood in arteries and draining vein effects from flowing blood in large veins can be suppressed by use of a DANTE preparation module. Using DANTE-prepared dual-echo EPI, we quantitatively measured intravascular-weighted microvascular CBV changes of 25.4%, 29.8%, and 32.6% evoked by 1, 5, and 10 Hz visual stimulation, respectively. The extravascular fraction (∆S/S)extra at TE = 30 ms in total BOLD signal was determined to be 64.8 ± 3.4%, which is in line with previous extravascular component estimation at 3 T. Results show that the microvascular CBV changes are linearly dependent on total BOLD changes at TE = 30 ms with a slope of 0.113, and this relation is independent of stimulation frequency and subject. CONCLUSION: The DANTE preparation pulses can be incorporated into a standard EPI fMRI sequence for the purpose of minimizing inflow effects and reducing draining veins effects in large vessels. Additionally, the DANTE-prepared dual-echo EPI sequence is a promising fast imaging tool for quantification of intravascular-weighted CBV change in the microvascular space at 3 T.

Original publication

DOI

10.1002/mrm.29099

Type

Journal article

Journal

Magn Reson Med

Publication Date

24/11/2021

Keywords

BOLD, DANTE-prepared dual-echo EPI, VASO, blood signal suppression, fMRI, quantification of CBV changes