Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Wrong blood in tube (WBIT) errors can lead to ABO mistransfusions. It is unknown if WBIT errors are more likely in specific healthcare locations or if specific collection practices influence the commission of WBIT errors. STUDY DESIGN AND METHODS: Data on pretransfusion samples from calendar year 2019 were collected retrospectively by 39 transfusion services in nine countries. We compared the proportion of WBIT errors made in emergency departments (EDs), inpatient wards, and outpatient clinics. RESULTS: In total, 143 WBIT errors were detected among 1,394,862 samples for an unadjusted aggregate WBIT proportion of 1.03/10,000 samples. Using a pooled random effects model, the WBIT proportion was estimated to be significantly higher in EDs (1.23/10,000 samples, 95% CI 0.62-2.43) than inpatient wards (0.71/10,000, 95% CI 0.44-1.14; p < .001) or outpatient clinics (0.24/10,000, 95% CI 0.08-0.65; p < .001) and significantly higher in inpatient wards than outpatient clinics (p = .043). The use of electronic positive patient identification (ePPID) systems was associated with a significantly lower WBIT proportion in the ED (odds ratio, OR: 0.32, 95% CI: 0.11-0.96, p = .041), but not in inpatient wards (OR: 0.45, 95% CI: 0.20-1.01, p = .054) or outpatient clinics (OR: 1.95, 95% CI: 0.39-9.74, p = .415). DISCUSSION: Normalized for the number of samples drawn per location, the WBIT proportion in EDs was 1.7 times higher than inpatient wards and 5.1 times higher than outpatient clinics. EDs represent higher-risk clinical locations for WBIT errors, and electronic positive patient identification (ePPID) may provide a greater impact on safety in EDs relative to other clinical areas.

More information Original publication

DOI

10.1111/trf.16588

Type

Journal article

Publication Date

2021-09-01T00:00:00+00:00

Volume

61

Pages

2601 - 2610

Total pages

9

Keywords

blood transfusion, patient safety, pretransfusion testing, specimen collection, Blood Donors, Blood Specimen Collection, Blood Transfusion, Cross-Sectional Studies, Emergency Service, Hospital, Humans, Medical Errors, Retrospective Studies, Transfusion Reaction