Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Abstract Purpose To demonstrate that vessel-selectivity in arterial spin labeling angiography can be achieved without any scan time penalty or noticeable loss of image quality compared to conventional arterial spin labeling angiography. Methods Simulations on a numerical phantom were used to assess whether the increased sparsity of vessel-encoded angiograms compared to non-vessel-encoded angiograms alone can improve reconstruction results in a compressed sensing framework. Further simulations were performed to study whether the difference in relative sparsity between non-selective and vessel-selective dynamic angiograms were sufficient to achieve similar image quality at matched scan times in the presence of noise. Finally, data were acquired from 5 healthy volunteers to validate the technique in vivo. All data, both simulated and in vivo, were sampled in 2D using a golden angle radial trajectory and reconstructed by enforcing both image domain sparsity and temporal smoothness on the angiograms in a parallel imaging and compressed sensing framework. Results Relative sparsity was established as a primary factor governing the reconstruction fidelity. Using the proposed reconstruction scheme, differences between vessel-selective and non-selective angiography were negligible compared to the dominant factor of total scan time in both simulations and in vivo experiments at acceleration factors up to R = 34. The reconstruction quality was not heavily dependent on hand-tuning the parameters of the reconstruction. Conclusion The increase in relative sparsity of vessel-selective angiograms compared to non-selective angiograms can be leveraged to achieve higher acceleration without loss of image quality, resulting in the acquisition of vessel-selective information at no scan time cost.

Original publication

DOI

10.1101/673475

Type

Journal article

Publication Date

18/06/2019