Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Insufficient techniques exist for rapid and reliable phenotype characterization of genetically manipulated mouse models of cardiac dysfunction. We developed a new, robust, 3-dimensional echocardiography (3D-echo) technique and hypothesized that this 3D-echo technique is as accurate as magnetic resonance imaging (MRI) and histology for assessment of left ventricular (LV) volume, ejection fraction, mass, and infarct size in normal and chronically infarcted mice. METHODS AND RESULTS: Using a high-frequency, 7/15-MHz, linear-array ultrasound transducer, we acquired ECG and respiratory-gated, 500-microm consecutive short-axis slices of the murine heart within 4 minutes. The short-axis movies were reassembled off-line in a 3D matrix by using the measured platform locations to position each slice in 3D. Epicardial and endocardial heart contours were manually traced, and a B-spline surface was fitted to the delineated image curves to reconstruct the heart volumes. Excellent correlations were obtained between 3D-echo and MRI for LV end-systolic volumes (r=0.99, P<0.0001), LV end-diastolic volumes (r=0.99, P<0.0001), ejection fraction (r=0.99, P<0.0001), LV mass (r=0.94, P<0.0019), and infarct size (r=0.98, P<0.0001). Also, excellent correlations were found between the 3D-echo-derived LV mass and necropsy LV mass in normal mice (r=0.99, P<0.0001), as well as for 3D-echo-derived infarct size and histologically determined infarct size (r=0.99, P<0.0001) in mice with chronic heart failure. Bland-Altman analysis showed excellent limits of agreement between techniques for all measured parameters. CONCLUSIONS: This new, fast, and highly reproducible 3D-echo technique should be of widespread applicability for high-throughput murine cardiac phenotyping studies.

Original publication

DOI

10.1161/01.CIR.0000142049.14227.AD

Type

Journal article

Journal

Circulation

Publication Date

21/09/2004

Volume

110

Pages

1632 - 1637

Keywords

Animals, Disease Models, Animal, Echocardiography, Three-Dimensional, Heart Ventricles, Magnetic Resonance Imaging, Male, Mice, Mice, Inbred C57BL, Myocardial Infarction, Organ Size, Phenotype, Reproducibility of Results, Stroke Volume