We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Mitral isthmus ablation is challenging. The use of steerable sheath and high ablation power may improve success rate. METHODS: This single-center, prospective study enrolled 200 patients who underwent ablation for atrial fibrillation (AF), including mitral isthmus ablation. Mitral isthmus ablation was performed using an irrigated ablation catheter via a steerable sheath (endocardium: maximum power: 40/50 W limited to annular end, maximum temperature: 48 °C; coronary sinus [CS]: maximum power: 25/30 W, maximum temperature: 48 °C). Endpoint was bidirectional mitral isthmus block. RESULTS: Mitral isthmus block was acutely achieved in 182/200 patients (91%). Sixty-nine percent of patients required CS ablation. Mean total ablation time was 13 ± 6 minutes. There was 1 case of acute circumflex artery occlusion. Mean left atrium (LA) diameter was significantly bigger in patients with unsuccessful mitral isthmus ablation (49 ± 4 mm vs. 43 ± 6 mm; P = 0.0007). In redo procedures, the incidence of reconduction at the mitral isthmus, roof and cavotricuspid isthmus was 44%, 37%, and 29%, respectively. Overall incidence of perimitral flutter was 9%. Prior complex fractionated atrial electrogram ablation was a predictor for microreentrant atrial tachycardia (AT) whereas gaps in linear lesions predicted macroreentrant flutters. After a mean follow-up of 20 ± 9 months, 73% of patients remained free from AF or AT. CONCLUSION: We reported on a series of mitral isthmus ablation using steerable sheath and high ablation power (50 W). Larger LA diameter was a predictor of failure to achieve mitral isthmus block. The mitral isthmus had a moderately high incidence of re-conduction but was only associated with a relatively low incidence of perimitral flutter.

Original publication

DOI

10.1111/j.1540-8167.2012.02380.x

Type

Journal article

Journal

J Cardiovasc Electrophysiol

Publication Date

11/2012

Volume

23

Pages

1193 - 1200

Keywords

Aged, Atrial Fibrillation, Atrial Flutter, Cardiac Catheters, Catheter Ablation, Chi-Square Distribution, Electrocardiography, Electrophysiologic Techniques, Cardiac, England, Equipment Design, Female, Humans, Logistic Models, Male, Middle Aged, Mitral Valve, Multivariate Analysis, Prospective Studies, Recurrence, Reoperation, Tachycardia, Supraventricular, Therapeutic Irrigation, Time Factors, Treatment Outcome