We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Imaging based on magnetic resonance (MRI) for mapping and imaging of the weak magnetic materials placed into the homogenous magnetic field of an imager is proposed. Samples made of weak magnetic material were theoretically computed, constructed, and tested on an MRI 0.178 T permanent magnet imager. In laboratory experiments, a homogeneous phantom (reference medium)-a container filled with doped water-was used. The resultant image represents the magnetic field variations (MFV) in the homogeneous phantom. For detection, a carefully tailored gradient-echo (GRE) imaging method, susceptible to magnetic field homogeneities, was used. The first results showed the feasibility of the method and some of the possibilities offered in this field for material research. © 2012 IEEE.

Original publication

DOI

10.1109/TMAG.2012.2191298

Type

Journal article

Journal

IEEE Transactions on Magnetics

Publication Date

08/08/2012

Volume

48

Pages

2334 - 2339