We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Dynamic (31) P-MRS with sufficiently high temporal resolution enables the non-invasive evaluation of oxidative muscle metabolism through the measurement of phosphocreatine (PCr) recovery after exercise. Recently, single-voxel localized (31) P-MRS was compared with surface coil localization in a dynamic fashion, and was shown to provide higher anatomical and physiological specificity. However, the relatively long TE needed for the single-voxel localization scheme with adiabatic pulses limits the quantification of J-coupled spin systems [e.g. adenosine triphosphate (ATP)]. Therefore, the aim of this study was to evaluate depth-resolved surface coil MRS (DRESS) as an alternative localization method capable of free induction decay (FID) acquisition for dynamic (31) P-MRS at 7 T. The localization performance of the DRESS sequence was tested in a phantom. Subsequently, two dynamic examinations of plantar flexions at 25% of maximum voluntary contraction were conducted in 10 volunteers, one examination with and one without spatial localization. The DRESS slab was positioned obliquely over the gastrocnemius medialis muscle, avoiding other calf muscles. Under the same load, significant differences in PCr signal drop (31.2 ± 16.0% versus 43.3 ± 23.4%), end exercise pH (7.06 ± 0.02 versus 6.96 ± 0.11), initial recovery rate (0.24 ± 0.13 mm/s versus 0.35 ± 0.18 mm/s) and maximum oxidative flux (0.41 ± 0.14 mm/s versus 0.54 ± 0.16 mm/s) were found between the non-localized and DRESS-localized data, respectively. Splitting of the inorganic phosphate (Pi) signal was observed in several non-localized datasets, but in none of the DRESS-localized datasets. Our results suggest that the application of the DRESS localization scheme yielded good spatial selection, and provided muscle-specific insight into oxidative metabolism, even at a relatively low exercise load. In addition, the non-echo-based FID acquisition allowed for reliable detection of ATP resonances, and therefore calculation of the specific maximum oxidative flux, in the gastrocnemius medialis using standard assumptions about resting ATP concentration in skeletal muscle.

Original publication

DOI

10.1002/nbm.3196

Type

Journal article

Journal

NMR Biomed

Publication Date

11/2014

Volume

27

Pages

1346 - 1352

Keywords

7 T, DRESS localization, dynamic 31P-MRS, energy metabolism, gastrocnemius muscle, Adenosine Triphosphate, Energy Metabolism, Exercise, Humans, Hydrogen-Ion Concentration, Magnetic Resonance Spectroscopy, Muscle Contraction, Muscle, Skeletal, Oxidative Phosphorylation, Phantoms, Imaging, Phosphates, Phosphocreatine, Phosphorus Isotopes