Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): Clarendon Fund, John Fell Oxford University Press Research Fund, Oxford BHF Centre of Research Excellence (RE/18/3/34214), Alison Brading Memorial Graduate Scholarship in Medical Science, National Institute for Health Research Oxford Biomedical Research Centre, National Institutes of Health (R01HL144706). Background Right ventricular (RV) function evaluation is an integral part of comprehensive cardiac assessment, including for pulmonary hypertension, congenital heart disease and arrhythmogenic RV cardiomyopathy (ARVC) [1]. It is commonly assessed by measuring tricuspid annular plane systolic excursion (TAPSE) and peak systolic velocity (RV s’) on echocardiography [2]. However, it is highly sensitive to imaging window and small changes in the beam angle, limiting reliability [3]. Cardiovascular magnetic resonance (CMR) is the imaging gold-standard for assessing RV structure and function, and is highly reproducible. CMR can assess tricuspid valve (TV) motion using four-chamber (4Ch) and RV two-chamber (2Ch) cines, with high diagnostic performance when compared against single-plane analysis [4]. However, manual placement of the TV insertion points is highly time-consuming for routine clinical workflows. TVnet, a deep-learning framework for automatically tracking the TV in 4Ch cines [5] has been recently validated, but without the orthogonal plane (RV 2Ch) which is helpful to more reliably characterise TV motion. Purpose We further extend TVnet to automatically track RV 2Ch cines and derive analysis of global TV motion parameters (global TAPSE and RV s’) on par with expert level performance. Methods 74 patients undergoing CMR (1.5T Siemens MR scanner) with 4Ch and RV 2Ch views were retrospectively included in this ethically-approved study. The patients had the following cardiovascular conditions: myocardial infarction (n=43), ARVC (n=28) and Takotsubo cardiomyopathy (n=3). The dual-stage deep-learning pipeline with a residual neural network backbone [5, 6] (Figure 1A) was trained using 69 patient datasets and 15 patients were randomly chosen for testing. The TVnet trained on 4Ch cines [5] was used to automatically annotate the 4Ch cines of the testing set for global analysis comparison. For manual reference, the software Segment [7] was used to manually annotate the TV insertion points in all imaging data (1,865 RV 2Ch images, 375 4Ch images). The global TAPSE and RV s’ were derived as the mean perpendicular motion from the end-diastolic plane from both chamber views (Figure 1B). Results TVnet achieved a fast processing accuracy (<1 second per cine) and successfully tracked the TV insertion points from the RV 2Ch cine with a plane tracking error of 0.08±0.83 mm. The integrated pipeline yielded an excellent clinical-metric agreement with the manual reference (Figure 2) for both global TAPSE (error=0.42±0.68 mm, ICC=0.95) and RV s’ (error=-0.10±0.71 cm/s, ICC=0.85). Conclusion TVnet demonstrated excellent performance in both tracking the TV insertion points in RV 2Ch cines and deriving global TAPSE and RV s’ compared to manual reference. TVnet can eventually provide a complete automatic inline analysis of TV plane motion for a fast, reliable and reproducible assessment of RV function in routine clinical workflows. (A) TVnet pipeline (B) Metric derivationCorrelation and Bland-Altman plots

Original publication

DOI

10.1093/ehjci/jeac141.019

Type

Conference paper

Publisher

Oxford University Press (OUP)

Publication Date

23/08/2022

Volume

23