We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

The prevalence of atrial fibrillation (AF) is estimated at more than 3% in the adult population and there has been increased interest in screening for AF. In the SAFETY trial we chose to evaluate if inexpensive, wearable, consumer electrocardiography (ECG) sensing devices (Polar-H7 [PH7] and Firstbeat Bodyguard 2 [BG2]), could be used to detect AF accurately. We undertook a case-control study of 418 participants aged >65 (82 with AF and/or flutter at the study visit and 336 without) attending 3 general practice surgeries in Hampshire, UK for a single screening visit. The PH7 and BG2 devices were tested alongside 2 established AF detection devices (AliveCor and WatchBP) in random order and the diagnosis of AF was confirmed by 12-Lead ECG interpreted by a panel of cardiologists. The sensitivity (95% confidence interval [CI] range), specificity (95% CI range), and overall accuracy (95% CI range) of the 4 devices were: AliveCor: 87.8% (78.7% to 94.0%), 98.8% (97.0% to 99.7%), 96.7% (94.4% to 98.2%); WatchBP: 96.3% (89.7% to 99.2%), 93.5% (90.3% to 95.9%), 94.0% (91.3% to 96.1%): PH7: 96.3% (89.7% to 99.2%), 98.2% (96.2% to 99.3%), 97.9% (96.0% to 99.0%). BG2: 96.3% (89.7% to 99.2%), 98.5% (96.6% to 99.5%), 98.1% (96.3% to 99.2%). The PH7 and BG2 devices were highly reliable (the devices acquired sufficient data and obtained a diagnostic result in all but 1 participant on the first attempt). In conclusion, inexpensive, consumer heart rate monitoring devices (PH7 and BG2) can be used to detect AF accurately with sensitivity and specificity >95%. The consumer devices performed as well or better than WatchBP and AliveCor and have the capability to store or transmit ECG data which could be used to confirm AF.

More information Original publication

DOI

10.1016/j.amjcard.2018.07.003

Type

Journal article

Publication Date

2018-10-15T00:00:00+00:00

Volume

122

Pages

1339 - 1344

Total pages

5

Keywords

Aged, Algorithms, Atrial Fibrillation, Case-Control Studies, Electrocardiography, Ambulatory, England, Female, Humans, Male, Mass Screening, Sensitivity and Specificity