Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: In this analysis of the EWOLUTION registry, we evaluated the incidence, relevance and predictors of device-related thrombus in a large multi-center real-world cohort undergoing LAAc with the WATCHMAN device. METHODS AND RESULTS: We analyzed the 835 patients who underwent percutaneous LAA closure with the WATCHMAN device in the EWOLUTION registry in whom at least one TEE follow up was performed. Patients were 74 ± 9 y/o and were at high risk for stroke and bleeding (CHA2DS2-VASC-Score 4.3 ± 1.7; HAS-BLED-Score 2.3 ± 1.2). Device-related thrombus was detected in 4.1% (34/835) after a median of 54 days (IQR 42-111 days) with 91.2% (31/34) being detected within 3 months after the procedure or at the time of first TEE. Hereby DRT occurred irrespective of postprocedural anticoagulation. Patients with DRT more frequently had long-standing, non-paroxysmal atrial fibrillation (82.4 vs. 64.9%, p < .01), evidence of dense spontaneous echo contrast (26.5 vs. 11.9%, p = .03) and larger LAA diameters at the ostium (22.8 ± 3.5 vs. 21.1 ± 3.5 mm, p < .01) compared to patients without DRT. Left ventricular ejection fraction, device compression ratio and the incidence of renal dysfunction did not differ between the two groups. In a multivariate analysis, only non-paroxysmal atrial fibrillation identified as an independent predictor of developing DRT. Specific treatment of DRT was initiated in 62% (21/34) of patients whereas resolution was confirmed in 86% (18/21) of cases. Overall, no significant differences in annual rates of stroke/TIA or systemic embolism were observed in patients with or without DRT (DRT 1.7 vs. No-DRT 2.2%/year, p = .8). CONCLUSIONS: In real-world patients undergoing LAAc with the WATCHMAN device, DRT is rare. DRT was most frequently detected within the first 3 months after LAAc regardless of post-procedural regimen and was not associated with an increased risk of stroke or SE. While long-standing atrial fibrillation was the only independent factor associated with DRT, medical treatment of DRT resulted in a resolution of thrombi in most cases.

More information Original publication

DOI

10.1002/ccd.29458

Type

Journal article

Publication Date

2021-06-01T00:00:00+00:00

Volume

97

Pages

E1019 - E1024

Keywords

WATCHMAN, device-related thrombus, left atrial appendage, Atrial Appendage, Atrial Fibrillation, Humans, Incidence, Registries, Stroke, Stroke Volume, Thrombosis, Treatment Outcome, Ventricular Function, Left