Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: The spoiled gradient recalled echo (SPGR) sequence with variable flip angles (FAs) enables whole liver T 1 $$ {T}_1 $$ mapping at high spatial resolutions but is strongly affected by B 1 + $$ {B}_1^{+} $$ inhomogeneities. The aim of this work was to study how the precision of acquired T 1 $$ {T}_1 $$ maps is affected by the T 1 $$ {T}_1 $$ and B 1 + $$ {B}_1^{+} $$ ranges observed in the liver at 3T, as well as how noise propagates from the acquired signals into the resulting T 1 $$ {T}_1 $$ map. THEORY: The T 1 $$ {T}_1 $$ variance was estimated through the Fisher information matrix with a total noise variance including, for the first time, the B 1 + $$ {B}_1^{+} $$ map noise as well as contributions from the SPGR noise. METHODS: Simulations were used to find the optimal FAs for both the B 1 + $$ {B}_1^{+} $$ mapping and T 1 $$ {T}_1 $$ mapping. The simulations results were validated in 10 volunteers. RESULTS: Four optimized SPGR FAs of 2°, 2°, 15°, and 15° (TR = 4.1 ms) and B 1 + $$ {B}_1^{+} $$ map FAs of 65° and 130° achieved a T 1 $$ {T}_1 $$ coefficient of variation of 6.2 ± 1.7% across 10 volunteers and validated our theoretical model. Four optimal FAs outperformed five uniformly spaced FAs, saving the patient one breath-hold. For the liver B 1 + $$ {B}_1^{+} $$ and T 1 $$ {T}_1 $$ parameter space at 3T, a higher return in T 1 $$ {T}_1 $$ precision was obtained by investing FAs in the SPGR acquisition rather than in the B 1 + $$ {B}_1^{+} $$ map. CONCLUSION: A novel framework was developed and validated to calculate the SPGR T 1 $$ {T}_1 $$ variance. This framework efficiently identifies optimal FA values and determines the total number of SPGR and B 1 + $$ {B}_1^{+} $$ measurements needed to achieve a desired T 1 $$ {T}_1 $$ precision.

Original publication

DOI

10.1002/mrm.29683

Type

Journal article

Journal

Magn Reson Med

Publication Date

01/05/2023

Keywords

B 1 + $$ {B}_1^{+} $$ mapping, T 1 $$ {T}_1 $$ mapping, T 1 $$ {T}_1 $$ precision, liver, optimal flip angles