We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Radiation exposure is a major concern in cardiac device implantation, especially cardiac resynchronization therapy (CRT) procedures. The RadPad™ (Worldwide Innovations & Technologies, Inc., Kansas City, MO, USA), a radiation-attenuating adhesive drape, has been shown to be beneficial in several clinical settings involving fluoroscopy, but less is known about the actual benefits in CRT procedures. METHODS: Consecutive CRT implants performed with and without a RadPad™ drape over a 10-month period were analyzed. Two thermoluminescent dosimeters (TLDs) were attached to each implanting physician at several locations (adjacent to eyes, center abdomen [outside lead apron], left and right index fingers, and dorsum of the right foot). Results were corrected for background using control TLDs, and normalized to dose-area product (DAP). RESULTS: Thirty-six patients (31 male), 16 with and 20 without the RadPad™, were included in the study. No technical problems were caused by the presence of the radiation-absorbing drape. Time required to position the drape never exceeded 30 seconds, no acute skin reactions were noted, and no radiation-absorbing drape became displaced. Despite a trend toward longer fluoroscopy times and higher DAPs in the radiation-absorbing drape group, radiation exposure was significantly reduced: 65% in the case of the hands and body (P < 0.001), and 40% the eyes (P < 0.01). CONCLUSION: The use of a radiation-absorbing drape results in a significant reduction in radiation dose to the implanting physician during CRT procedures. Not only is the dose to the hands reduced, but also the eye and body doses are significantly reduced. The routine use of radiation-absorbing drapes should be considered for all CRT implant procedures in the light of these findings.

Original publication

DOI

10.1111/pace.12349

Type

Journal article

Journal

Pacing Clin Electrophysiol

Publication Date

07/2014

Volume

37

Pages

828 - 833

Keywords

CRT, cardiac pacemaker, defibrillator, exposure, radiation, radiation-absorbing drape, Aged, Bismuth, Cardiac Resynchronization Therapy, Cardiac Resynchronization Therapy Devices, Equipment Design, Female, Humans, Male, Radiation Dosage, Radiation Protection